CONTA-CLIP
Test-disconnect terminals are mostly used in the sectors of electricity generation and supply.They are tailored to the variety of switching
demands for current-converter secondary circuits that predominate in these sectors. Current transformers must always have a secondary
circuit when electricity meters and measuring instruments are being replaced, or when making comparative measurements.
CONTA-CLIP test-disconnect terminals are available in the following three basic versions, each with or without a pre-assembled socket plug.
All versions provide touch-safe protection according to DGUV-3.
A captive, screw-on sliding partition is used to separate the current and voltage paths.
The switch position is always easy to detect since the disconnect screw has a yellow insulating sleeve.
In all versions, the STB 14/4 socket plugs can be used for a test pick-off for measuring values using the PS 4 test plug or the conventional (4 mm) insulated test plugs.
The VH 19 connecting sleeves and the BS 25 screws or STB 14/4 socket plugs are required for fastening the QVS cross-switches above the terminal block. The cross-switches are available from 2 to 4 poles.
The QSB internal cross-switches are positioned within the terminal block and make contact over the sliding contact on the LT- or QT-terminals. The cross-switches are available from 2 to 4 poles.
The BS 25 mounting screws are used together with the VH 19 connecting sleeves to establish contact with the QVS cross-switches.
Approvals | CSA, CSA US |
---|---|
Color | Beige |
Connections | 2 |
Contamination degree | 3 |
Country of origin | DE |
Cross connect channels | 2 |
Cross section single wire from | 0,2 mm² |
Cross section single wire to | 10 mm² |
Cross section stranded wire from | 0,2 mm² |
Cross section stranded wire to | 10 mm² |
Cross section stranded with ferrule from | 0,2 mm² |
Cross section stranded with ferrule to | 10 mm² |
Cross-Section | 10 mm² |
CSA test standard | C22.2 No 158 |
CSAus test standard | UL 1059 |
Flammability class | UL94-V2 |
Height TS 32 | 51,5 mm |
Height TS 35/7.5 | 47 mm |
Insulation Material | Polyamide 6.6 |
Length | 72 mm |
Mounting | TS 35/7,5 and TS 32 |
Number of levels | 1 |
Operating temperature from | -40 °C |
Operating temperature to | 105 °C |
---|---|
Overvoltage category | III |
Pack Size | 50 |
Plug gauge acc. EN 60 947-1 | A5 |
Rated Current CSA | 45 A |
Rated current CSAus | 45 A |
Rated Current IEC | 10 A |
Rated impulse voltage | 4 kV |
Rated wire cross section from (AWG) | 8 |
Rated wire cross section to (AWG) | 22 |
Rated voltage CSAus | 600 V |
Rated Voltage IEC | 400 V |
Screw size | M 4 |
Screw type | Slotted |
Stripping Length | 12 mm |
Tariff code | 85369010 |
Torque max | 2 Nm |
Torque Min | 1,2 Nm |
Weight | 24,66 g |
Width | 8 mm |
Voltage CSA | 600 V |
Test-disconnect terminals are mostly used in the sectors of electricity generation and supply.They are tailored to the variety of switching
demands for current-converter secondary circuits that predominate in these sectors. Current transformers must always have a secondary
circuit when electricity meters and measuring instruments are being replaced, or when making comparative measurements.
CONTA-CLIP test-disconnect terminals are available in the following three basic versions, each with or without a pre-assembled socket plug.
All versions provide touch-safe protection according to DGUV-3.
A captive, screw-on sliding partition is used to separate the current and voltage paths.
The switch position is always easy to detect since the disconnect screw has a yellow insulating sleeve.
In all versions, the STB 14/4 socket plugs can be used for a test pick-off for measuring values using the PS 4 test plug or the conventional (4 mm) insulated test plugs.
The VH 19 connecting sleeves and the BS 25 screws or STB 14/4 socket plugs are required for fastening the QVS cross-switches above the terminal block. The cross-switches are available from 2 to 4 poles.
The QSB internal cross-switches are positioned within the terminal block and make contact over the sliding contact on the LT- or QT-terminals. The cross-switches are available from 2 to 4 poles.
The BS 25 mounting screws are used together with the VH 19 connecting sleeves to establish contact with the QVS cross-switches.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Additional information | Cross connect channels | Number of test pick off options | Weight | ||
---|---|---|---|---|---|---|
PTK 10/LT , Test-disconnect terminal
Art:
1130.2
Copied
|
|
2
|
|
24,66 g
|
| |
PTK 10/LT/STB, Test-disconnect terminal with sockets
Art:
1131.2
Copied
|
with sockets
|
|
2
|
28,9 g
|
| |
PTK 10/QT, Test-disconnect terminal, separated perpendicularly
Art:
1132.2
Copied
|
|
2
|
|
25,14 g
|
| |
PTK 10/QT, Test-disconnect terminal with sockets, separated perpendicularly
Art:
1133.2
Copied
|
with sockets
|
|
2
|
29,74 g
|
| |
PTK 10/DU, Test-disconnect feed through terminal
Art:
1134.2
Copied
|
|
2
|
|
22,56 g
|
| |
PTK 10/DU/STB,Test-disconnect feed through terminal with sockets
Art:
1135.2
Copied
|
with sockets
|
|
2
|
22,56 g
|
|
Select a variant in the list