CONTA-CLIP
The newest generation of stud terminals from CONTA-CLIP offers secure connections for all high power conductors.
The HSKG stud terminals are available with stud sizes of with M6, M8, M10, M12 and rated current is from 125 A to 520A at a rated voltage of 1000 V.
The wire connection range is from 2.5 mm² to 300 mm². and crimped lugs are used to fit the cables to the busbar using the hexagonal nut with built in washer.
When used together with the ADH hinged covers, the HSKG stud terminals provide outstanding finger and touch protection. The ADH cover is easy to mount; it simply snaps into the side walls of the stud terminals as it is closed.
In this quick and reliable way, touch-safe protection of the terminal points is always guaranteed.
Added features include -
Approvals | UL, CSA, CSA US, cUL, KEMA KUR |
---|---|
Color | Beige |
Connections | 2 |
Contact clamping area | ≤ 50 mm² |
Contamination degree | 3 |
Country of origin | DE |
Cross-Section | 35 mm² |
CSA test standard | C22.2 No 158 |
CSAus test standard | UL 1059 |
cUL test standard | C22.2 No 158 |
DIN 46234 / 1 cable lug per side, max. | 50 mm² |
DIN 46234 / 1 cable lug per side, min. | 2,5 mm² |
DIN 46235: 1 cable lug per side, max. | 25 mm² |
DIN 46235: 1 cable lug per side, min. | 6 mm² |
Flammability class | UL94-V0 |
Height TS 35/7.5 | 51 mm |
Height with TW/ADH | 60 mm |
Insulation Material | Polyamide 6.6 |
KEMA KEUR test standard | EN 60947-7-1:2028 |
Length | 107 mm |
Length with TW/ADH | 131 mm |
Mounting | TS 35/7,5 |
Number of levels | 1 |
Operating temperature from | -40 °C |
Operating temperature to | 120 °C |
---|---|
Overvoltage category | III |
Pack Size | 10 |
Rated Current CSA | 130 A |
Rated current CSAus | 130 A |
Rated current cUL | 130 A |
Rated Current IEC | 125 A |
Rated impulse voltage | 8 kV |
Rated wire cross section from (AWG) | 14 |
Rated wire cross section to (AWG) | 1/0 |
Rated voltage CSAus | 1000 V |
Rated voltage cUL | 1000 V |
Rated Voltage IEC | 1000 V |
Rated Voltage To UL | 1000 V |
Stud size | M 6 |
Tariff code | 85369010 |
Torque max | 6 Nm |
Torque Min | 3 Nm |
UL test standard | UL 1059 |
Weight | 88,6 g |
Width | 27 mm |
Voltage CSA | 1000 V |
The newest generation of stud terminals from CONTA-CLIP offers secure connections for all high power conductors.
The HSKG stud terminals are available with stud sizes of with M6, M8, M10, M12 and rated current is from 125 A to 520A at a rated voltage of 1000 V.
The wire connection range is from 2.5 mm² to 300 mm². and crimped lugs are used to fit the cables to the busbar using the hexagonal nut with built in washer.
When used together with the ADH hinged covers, the HSKG stud terminals provide outstanding finger and touch protection. The ADH cover is easy to mount; it simply snaps into the side walls of the stud terminals as it is closed.
In this quick and reliable way, touch-safe protection of the terminal points is always guaranteed.
Added features include -
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Approvals | Bureau Veritas test standard | Contact clamping area | Cross-Section | CSA test standard | CSAus test standard | DIN 46234 / 1 cable lug per side, max. | DIN 46234 / 1 cable lug per side, min. | DIN 46234 / 2 cable lugs per side, max. | DIN 46234 / 2 cable lugs per side, min. | DIN 46235: 1 cable lug per side, max. | DIN 46235: 1 cable lug per side, min. | DIN 46235: 2 cable lugs per side, max. | DIN 46235: 2 cable lugs per side, min. | EAC test standard | GL test standard | Height TS 35/7.5 | Height with TW/ADH | KEMA KEUR test standard | Length | Length with TW/ADH | Pack Size | Rated Current CSA | Rated current CSAus | Rated current cUL | Rated Current IEC | Rated wire cross section from (AWG) | Rated wire cross section to (AWG) | Rated voltage CSAus | Stud size | Torque max | Torque Min | Weight | Width | Voltage CSA | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HSKG 35/M6/B/B, 35mm² Dual M6 stud terminal
Art:
17170.2
Copied
|
UL, CSA, CSA US, cUL, KEMA KUR
|
|
≤ 50 mm²
|
35 mm²
|
C22.2 No 158
|
UL 1059
|
50 mm²
|
2,5 mm²
|
|
|
25 mm²
|
6 mm²
|
|
|
|
|
51 mm
|
60 mm
|
EN 60947-7-1:2028
|
107 mm
|
131 mm
|
10
|
130 A
|
130 A
|
130 A
|
125 A
|
14
|
1/0
|
1000 V
|
M 6
|
6 Nm
|
3 Nm
|
88,6 g
|
27 mm
|
1000 V
|
| |
HSKG 70/M8/B/B, 70mm² Dual M8 stud terminal
Art:
17035.2
Copied
|
UL, CSA, CSA US, cUL, KEMA KUR
|
|
≤ 95 mm²
|
70 mm²
|
C22.2 No 158
|
UL 1059
|
95 mm²
|
2,5 mm²
|
|
|
70 mm²
|
16 mm²
|
|
|
|
|
61 mm
|
70 mm
|
EN 60947-7-1:2009
|
132 mm
|
180 mm
|
10
|
175 A
|
175 A
|
175 A
|
192 A
|
14
|
3/0
|
1000 V
|
M 8
|
12 Nm
|
6 Nm
|
156,2 g
|
32 mm
|
1000 V
|
| |
HSKG 120/M10/B/B, 120mm² Dual M10 stud terminal
Art:
17023.2
Copied
|
UL, GL, cUL, KEMA KUR, EAC
|
IEC 60947-7-1
|
≤ 120 mm²
|
120 mm²
|
|
|
15 mm²
|
6 mm²
|
120 mm²
|
6 mm²
|
150 mm²
|
16 mm²
|
120 mm²
|
16 mm²
|
TR ZU 004/2011
|
IEC 60947-7-1:2009
|
72 mm
|
80 mm
|
EN 60947-7-1:2009
|
133 mm
|
226 mm
|
5
|
|
|
310 A
|
269 A
|
10
|
250 Kcmil
|
|
M 10
|
20 Nm
|
10 Nm
|
245,7 g
|
42 mm
|
|
| |
HSKG 185/M12/B/B, 185mm² Dual M12 stud terminal
Art:
17024.2
Copied
|
UL, GL, cUL, KEMA KUR, EAC
|
IEC 60947-7-1
|
≤ 185 mm²
|
185 mm²
|
|
|
240 mm²
|
10 mm²
|
185 mm²
|
10 mm²
|
240 mm²
|
25 mm²
|
185 mm²
|
25 mm²
|
TR ZU 004/2011
|
IEC 60947-7-1:2009
|
78 mm
|
90 mm
|
EN 60947-7-1:2009
|
164 mm
|
288 mm
|
5
|
|
|
380 A
|
353 A
|
8
|
500 Kcmil
|
|
M 12
|
31 Nm
|
14 Nm
|
409 g
|
55 mm
|
|
| |
HSKG 300/M16/B/B, 300mm² Dual M16 stud terminal
Art:
17027.2
Copied
|
UL, GL, cUL, KEMA KUR, EAC
|
IEC 60947-7-1
|
≤ 300 mm²
|
300 mm²
|
|
|
240 mm²
|
25 mm²
|
240 mm²
|
50 mm²
|
300 mm²
|
50 mm²
|
240 mm²
|
50 mm²
|
TR ZU 004/2011
|
IEC 60947-7-1:2009
|
86 mm
|
90 mm
|
EN 60947-7-1:2009
|
164 mm
|
288 mm
|
5
|
|
|
510 A
|
520 A
|
6
|
600 Kcmil
|
|
M 16
|
60 Nm
|
25 Nm
|
529 g
|
55 mm
|
|
|
Select a variant in the list