RM34 relay is used for temperature metering. Features a Pt100 sensor (DIN43760) with 2 or 3 wires. You can select between 4 metering ranges. Relay activation, inversion and delay are adjusted by DIP switches in the bottom of the relay. Relay will release in the occasion of short-circuit or cable breakage.
Supply | 12 – 50 V DC or 230 V AC |
Isolation voltage | Supply-input-output 3,75 kV |
Power consumption | 3 VA |
Temperature range | -20 °C...+60 °C |
Temp. coefficient | <0,01 %/ºC |
Indications | Green LED steady: |
DIP-switches | S1-S2: relay inversion and reaction delay, see table and functional diagram |
Potentiometers | Pot 1 setpoint , 0-100% of the range |
Hysteresis | 1 °C |
Sensor connections | 6-7 Pt100 |
Max. load, relay | relay 1 (1-3-4) 8 A – 250 V AC |
Weight | 190 g |
EMC | EN50081-1, EN50082-2, EN60730, CE |
SW 1 | SW 2 | ex. no. | Function |
Off | Off | 1 | Relay activates, when setpoint is exceeded, delay on release. |
On | Off | 2 | Relay releases, when setpoint is exceeded, delay on activate. |
Off | On | 3 | Delay on activate, when setpoint is exceeded. |
On | On | 4 | Delay on release, when setpoint is exceeded. |
SW 3 | SW 4 | Mittausalue | |
Off | Off | -50 °C...+50 °C | |
On | Off | 0 °C...100 °C | |
Off | On | 50 °C...150 °C | |
On | On | 100 °C...200 °C |
Order number | Description | Supply |
RM3421.230 | Temperature relay | 230 V AC |
RM3424.012 | Temperature relay | 12-50 V DC |
Approvals | CE, EMC |
---|---|
Depth | 74 mm |
Height | 76 mm |
Hysteresis Temperature | 1,5 |
IP Class | IP20 |
Materials Cover | Noryl |
Mounting | DIN rail |
Power Supply DC max | 50 V |
---|---|
Power Supply DC min | 12 V |
Temperature resistance housing from | -20 °C |
Temperature resistance housing to | 60 °C |
Weight | 190 g |
Width | 38 mm |
RM34 relay is used for temperature metering. Features a Pt100 sensor (DIN43760) with 2 or 3 wires. You can select between 4 metering ranges. Relay activation, inversion and delay are adjusted by DIP switches in the bottom of the relay. Relay will release in the occasion of short-circuit or cable breakage.
Supply | 12 – 50 V DC or 230 V AC |
Isolation voltage | Supply-input-output 3,75 kV |
Power consumption | 3 VA |
Temperature range | -20 °C...+60 °C |
Temp. coefficient | <0,01 %/ºC |
Indications | Green LED steady: |
DIP-switches | S1-S2: relay inversion and reaction delay, see table and functional diagram |
Potentiometers | Pot 1 setpoint , 0-100% of the range |
Hysteresis | 1 °C |
Sensor connections | 6-7 Pt100 |
Max. load, relay | relay 1 (1-3-4) 8 A – 250 V AC |
Weight | 190 g |
EMC | EN50081-1, EN50082-2, EN60730, CE |
SW 1 | SW 2 | ex. no. | Function |
Off | Off | 1 | Relay activates, when setpoint is exceeded, delay on release. |
On | Off | 2 | Relay releases, when setpoint is exceeded, delay on activate. |
Off | On | 3 | Delay on activate, when setpoint is exceeded. |
On | On | 4 | Delay on release, when setpoint is exceeded. |
SW 3 | SW 4 | Mittausalue | |
Off | Off | -50 °C...+50 °C | |
On | Off | 0 °C...100 °C | |
Off | On | 50 °C...150 °C | |
On | On | 100 °C...200 °C |
Order number | Description | Supply |
RM3421.230 | Temperature relay | 230 V AC |
RM3424.012 | Temperature relay | 12-50 V DC |
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Approvals | Depth | Height | Hysteresis Temperature | IP Class | Materials Cover | Mounting | Power Supply DC max | Power Supply DC min | Temperature resistance housing from | Temperature resistance housing to | Weight | Width | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TEMP.RELÄ PT100,-50-200°C,24DC
Art:
RM3424.012
Copied
|
CE, EMC
|
74 mm
|
76 mm
|
1,5
|
IP20
|
Noryl
|
DIN rail
|
50 V
|
12 V
|
-20 °C
|
60 °C
|
190 g
|
38 mm
|
| |
LT relay PT100, -50…+200 °C, 230 V AC
Art:
RM3421.230
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Select a variant in the list