PULS

Redundant module 20 A Piano Series

The PIRD20.241 is a redundancy module, which can be used to build 1+1 and N+1 redundant systems. It is equipped with two input channels, which can be connected to power supplies with up to 10A output current and one output, which can carry nominal currents up to 20A. The module is suitable for power supplies with constant current overload behavior as well as any kind of “hiccup” overload behavior. The PIRD20.241 is the perfect solution to use in a redundant system, if the power supply itself is equipped with a DC-OK signal. Another application for this redundancy module is to separate sensitive loads from non-sensitive loads. This avoids the distortion of the power quality for the sensitive loads which can cause controller failures.

 

Read more
  • 39 mm wide
  • Two diodes
  • Screw terminals
  • Cost effective solution

Selected variant

REDUNDANCY MODULE 12-24V 2x10A PIANO

REDUNDANCY MODULE 12-24V 2x10A PIANO

Art:

Selected variant

Specifications

Input voltage DC 12-28 V
Input voltage dc min 9 V DC
Input voltage dc max 35 V DC
Input current per channel max 10 A
Type Power Supply Redundancy modules
Output voltage 24 V DC
Output Current 20 A
Output current max 26 A
Temperature Range Without Derating From -40 °C
Temperature Range Without Derating To 55 °C
Width 39 mm
Height 124 mm
Depth 124 mm
Weight 0,28 kg
Series Piano
Approvals ATEX, CE, CSA, IECEx, UL
Material Protection ABS plastic
IP Class IP20
Voltage Drop Over The Semi-Conductor 560 mV

Product description

The PIRD20.241 is a redundancy module, which can be used to build 1+1 and N+1 redundant systems. It is equipped with two input channels, which can be connected to power supplies with up to 10A output current and one output, which can carry nominal currents up to 20A. The module is suitable for power supplies with constant current overload behavior as well as any kind of “hiccup” overload behavior. The PIRD20.241 is the perfect solution to use in a redundant system, if the power supply itself is equipped with a DC-OK signal. Another application for this redundancy module is to separate sensitive loads from non-sensitive loads. This avoids the distortion of the power quality for the sensitive loads which can cause controller failures.

 

Accessories

Related products

Contact us
Please contact us for more information.
Send e-mail
Do you need help?
Logo

Cookies on oem.ee

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

Functional cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analytics cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.