PULS
The ML100.200 is a simple and cost effective approach to convert the ac voltage of a typical three phase system into a regulated dc voltage. It only requires two phases and thereby saves terminal space, terminal cost, wires, fuses and installation time.
The ML100.200 is very compact, high efficient and easy to use. The input is internally protected, which makes external fuses unnecessary in many cases.
Weighing only 360g, it is a lightweight compared to the 50/60Hz control transformers, which are commonly used for low-power control voltages where a neutral wire is not available.
High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible.
For approved cooling, free space of 40 mm above and 20 mm under is recommended.
If adjacent components on the rail radiate heat, free space of 15 mm is recommended at all sides.
Input voltage range | Wide-range |
---|---|
Number of phases | 2 |
Input voltage AC | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 552 V AC |
Inrush current at 400 V ac typical | 36 A |
Power Factor at 400 V AC, full load. Typical | 0,6 |
Supply Frequency | 50-60 ±6 % |
Power consumption at 400 V ac | 0,42 A |
Type Power Supply | AC-DC |
Output voltage | 24 V DC |
Output voltage min | 24 V DC |
Output voltage max | 28 V DC |
Output Current | 3,75 A |
Effect | 90 W |
Power Reduction Of 60 To 70 ° C | 2 W/°C |
Ripple. max | 50 mV pp |
---|---|
Temperature Range Without Derating From | -10 °C |
Temperature Range Without Derating To | 60 °C |
Efficiency At 400 V AC, full load. Typical | 89,5 % |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 1594000 h |
Width | 72,5 mm |
Height | 75 mm |
Depth | 103 mm |
Weight | 0,36 kg |
Clamp type | Spring-clamp |
Series | Miniline |
Approvals | CB, CE, CSA, GL, NEC Class 2, UL |
Material Protection | ABS plastic |
Hold-up time at 400 V AC, full load. Typical. | 52 ms |
IP Class | IP20 |
The ML100.200 is a simple and cost effective approach to convert the ac voltage of a typical three phase system into a regulated dc voltage. It only requires two phases and thereby saves terminal space, terminal cost, wires, fuses and installation time.
The ML100.200 is very compact, high efficient and easy to use. The input is internally protected, which makes external fuses unnecessary in many cases.
Weighing only 360g, it is a lightweight compared to the 50/60Hz control transformers, which are commonly used for low-power control voltages where a neutral wire is not available.
High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible.
For approved cooling, free space of 40 mm above and 20 mm under is recommended.
If adjacent components on the rail radiate heat, free space of 15 mm is recommended at all sides.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Articles | Output voltage | Input voltage AC | Clamp type | Effect | Output Current | ||
---|---|---|---|---|---|---|---|
PULS PSU 90W 24-28VDC 2 PHASE
Art:
ML90.200
Copied
|
24 V DC
|
380-480 V
|
Spring-clamp
|
90 W
|
3,75 A
|
| |
PULS PSU 100W 24-28VDC 2 PHASE
Art:
ML100.200
Copied
|
24 V DC
|
380-480 V
|
Spring-clamp
|
100 W
|
4,2 A
|
|
Select a variant in the list